Metal roof coating
Coating an aged metal panel roof is a restoration system, not a paint job: the crew treats rust, replaces bad fasteners and seals the laps, then coats the whole roof. Makers limit it to panels that are still sound, with a worn finish and surface rust. Silicone, acrylic and polyurethane systems are all sold for it, with warranties tied to coating thickness.
- Good candidate
- Sound panels with a worn finish and surface rust
- Coatings used
- Silicone, acrylic, polyurethane and others
- Fasteners
- Bad ones replaced with oversized screws; every head sealed
- Laps and seams
- Resealed, then reinforced with fabric or seam tape
- Extra area for ribs
- About 15 to 40%, by profile
- Warranty available
- 5 to 20 years by thickness
What a coating can and can't fix
Makers aim metal restoration at a worn finish and surface rust. Gaco limits its metal-roof coatings to panels in sound condition that need their finish renewed, and says the coating seals the roof only together with seam restoration and fastener replacement. The manufacturers' association (RCMA) notes that a factory finish degrades with age, exposed fasteners can leak, and the sealant in the panel laps breaks down.
Those are the places a federal study of metal buildings found corrosion first: laps and seams, eaves and panel edges. An IIBEC paper on hail dents adds end laps and over-tightened fasteners.
A coating doesn't put back lost metal. Karnak says panels rusted through must be replaced, Henry says to replace weakened or corroded panels, and the federal study says panels with metal missing should be repaired or replaced. American WeatherStar warns that hidden rust between panels or on the underside can't be fixed by a coating, and RCMA treats widespread red rust as repair work beyond a coating job.
Wet insulation comes out first. Garland, Henry and Mule-Hide say not to coat over wet or saturated insulation, Henry lists infrared scans among survey methods, and Mule-Hide says enough wet material can mean replacing the whole roof.
Low slope is a limit too. Gaco's acrylic and polyurethane metal specs aren't intended for slopes under 2:12 or surfaces that pond, and the federal study recommends replacing a metal roof that leaks for lack of slope with a roof designed for low slope. Gaco and Henry also exclude cold-storage buildings, and Henry requires metal heavier than 28 gauge.
Pros and cons
Where metal roof coatings work
- Done with fastener replacement and seam work, it makes the roof weathertight again without tearing off the panels.
- Karnak's base coat encapsulates surface rust and inhibits new rust on properly prepared metal.
- A white coating makes bare metal reflective: 0.87 new for Gaco's S42.
- Several makers offer 20-year warranties on metal at enough thickness.
Where they fall short
- It can't fix panels rusted through, or rust hidden between laps and on the underside.
- Low-slope metal that ponds is a poor candidate.
- Factory PVDF (Kynar) and siliconized finishes are hard to coat, and some makers exclude them.
- Ribs add about 15 to 40% more surface to coat.
- The warranty covers the coating, not the existing roof under it.
How a metal roof is restored
- Inspect the panels, including the underside where possible, and survey for wet insulation. Mule-Hide requires a moisture survey report for a system warranty.
- Wash the whole roof: at more than 2,000 psi for Henry and Garland and 3,000 psi for Gaco and American WeatherStar, to strip dirt, chalking, loose rust and flaking coatings. Algae and mildew get a bleach solution, and Mule-Hide wipes the dry metal with a clean rag and washes again if it picks up chalk.
- Remove loose rust down to sound metal, by wire brush, blasting or power tools, and prime rusted areas with a rust-inhibitive primer. Polyglass puts two coats on medium to heavy rust.
- Test adhesion and prime the finish if needed. Henry requires at least 2 pounds per inch on at least two tests, and the federal spec calls for three tests on each type of surface. New galvanized steel has to weather first, a year for Gaco or 90 days for American WeatherStar, unless it's treated.
- Fix the fasteners. Loose ones are tightened; stripped, missing or corroded ones are replaced with oversized screws and new neoprene washers. The federal study warns against over-tightening fasteners with rubber washers. Then every exposed fastener head is encapsulated in sealant or coating with no trapped air.
- Seal the laps. Old mastics and silicone caulk come off, and laps that gap more than 1/8 inch are stitch-fastened closed. Gaco takes leaking end laps apart and remakes them with new butyl. Horizontal laps then get a 4- to 6-inch strip of polyester fabric set in base coat, or a butyl seam tape. Intact, factory-crimped seams often need nothing.
- Secure skylights, gutters, curbs and penetrations. Karnak replaces damaged skylights, and American WeatherStar says never to coat fiberglass skylight panels, because a coated panel looks walkable and becomes a fall risk.
- Coat the field, with an extra pass at edges, standing seams and vertical ribs, and check wet thickness as it goes on.
Thermal movement
Metal panels expand and contract with temperature, and long panels can move several inches. NRCA's Professional Roofing calls metal roofs the least forgiving of all roof systems when that movement is ignored.
So the coating has to stretch and recover, which RCMA calls important properties for metal roofs, and the details are built to move. American WeatherStar uses a thick rubber-like mastic at seams and flashings, and the federal coating spec puts a bond-break tape over moving joints and laps before reinforcing them.
Ordering coating for ribbed panels
Ribbed and corrugated panels have more surface than the flat area of the roof, so makers add a stretch or surface factor before figuring gallons: Gaco normally 15 to 40%, Henry 15 to 30%, American WeatherStar 15% on average, and Polyglass a multiplier of 1.2 or 1.3 depending on the profile. Garland says to use the factor for the specific panel.
Silicone, acrylic or polyurethane
Makers sell metal restoration systems in several chemistries: silicone, acrylic and polyurethane, plus polyurea from Garland, a SEBS rubber coating from Karnak and aluminum-pigmented asphalt from Karnak and Tremco.
RCMA's 2004 note on metal roofs called pigmented latex the most common coating and said polyurethane is often used where industrial chemicals or oils are present. The federal coating spec, which accepts existing metal roofs, uses polyurethane or silicone in an FM 4470 approved system at least 50 dry mils thick everywhere.
The finish on the panels narrows the choice. Gaco excludes siliconized and fluorocarbon (PVDF) finishes, and Henry's guides exclude Kynar or Hylar coated roofs. Tremco grinds PVDF finishes to bright metal and primes them, and Garland accepts Kynar-coated metal only over its metal primer.
Warranties and thickness
Gaco and American WeatherStar separate the material warranty, that the coating meets its published properties, from the applicator's workmanship guarantee. American WeatherStar gives a no-dollar-limit (NDL) warranty only on panels fastened into metal purlins with gasketed screws; roofs nailed or screwed into wood get a material-only warranty, if accepted at all.
System warranties need an approved applicator and approval before work starts: American WeatherStar approves each job, Mule-Hide requires a moisture survey and adhesion tests submitted first, and Garland inspects the treated seams and details before the field coat goes on.
The warranty covers the coating, not the roof under it. Mule-Hide's excludes leaks from the existing roof surface, Garland says failure of the substrate isn't failure of its coating, and Gaco excludes areas left uncoated under rooftop units that weren't lifted.
Makers' metal-roof specs set dry thickness by warranty term, and Gaco recommends adding 10% so the job still qualifies:
- Gaco silicone: 18 dry mils for 10 years, 34 for 20.
- Henry silicone: 22, 30 and 37 dry mils for 10, 15 and 20 years.
- American WeatherStar silicone: 20, 25 and 30 dry mils (theoretical totals) for 12, 15 and 20 years.
- Mule-Hide silicone: 22 dry mils for 10- and 15-year system warranties, 29 for 20.
- Henry acrylic: 26, 30 and 43 dry mils for 10, 15 and 20 years.
- Polyglass acrylic: 20, 24 and 30 dry mils for 10, 15 and 20 years.
- Gaco acrylic: one 12-mil coat for 5 years, three (36 dry mils) for 20.
- Gaco polyurethane: 23 dry mils for 10 years, 36 for 20.
- The federal coating spec: at least 50 dry mils everywhere, an NDL manufacturer warranty of 5, 10 or 20 years, and a 2- or 5-year contractor warranty.
Reflectance
A white coating can make bare or faded metal reflective. Gaco's S42 silicone, which it recommends for metal roofs, lists 0.87 solar reflectance new and 0.69 after three years, and its white urethane top coat 0.85. Tremco says its aluminum Alumanation 301 reflects up to 66% of sunlight.
American WeatherStar warns that reflectance may drop if the roof isn't cleaned on a regular schedule.
Codes and approvals
The 2021 International Building Code allows a new protective roof coating over existing metal roof panels without tearing them off; the same exception covers built-up, spray foam, modified bitumen and single-ply roofs.
FM Approvals' standard for panel roofs, FM 4471, tests the whole assembly for fire, coating included, because a coating can support combustion. Its hail test fails panels whose coating chips, peels or cracks under 10X magnification.
Other coatings
- Silicone roof coatingHow silicone roof coating cures, what makers claim on ponding water and what warranties cover, why only silicone sticks to it, and the dry mils required.
- Acrylic roof coatingAcrylic elastomeric roof coating explained: the ASTM D6083 types, weather limits, why makers keep it off ponding water, fabric details and warranty mils.
- Polyurethane roof coatingPolyurethane roof coating explained: aromatic base and aliphatic top coats, toughness for traffic and hail, solvent safety, ponding and warranty mils.
Roof systems
- Commercial metal roofingHow standing seam and exposed-fastener steel roofs go on, the slope they need, where they fall short, how they take hail, and what the warranties cover.
- Spray foam roofingHow spray polyurethane foam roofs go over old roofs or bare decks, where they fit, how they handle hail, and the warranties manufacturers offer.
Calculator
- Roof coating calculatorEstimate the gallons and 5-gallon pails of roof coating you need from roof area, the dry mils your spec requires and the product's volume solids.
Sources
- Gaco (Amrize Building Envelope), Application Specification MR-S42-34-20: GacoFlex S42 Series Elastomeric Silicone Roof Coating for Restoring Aged Metal Roofing Systems (rev. 10/2025)
- Karnak Corporation, Roof Restoration System METAL 502B-502W: white reflective coating system application guidelines
- American WeatherStar, Met-A-Sil Roof Restoration System quick spec
- Gaco (Amrize Building Envelope), Application Specification MR-A47-36-20: GacoFlex A47 Series Acrylic Roof Coating for Restoring Aged Metal Roofing Systems (rev. 1/2026)
- Gaco (Amrize Building Envelope), Application Specification MR-U91U92-36-20: GacoFlex U91 & U92 Polyurethane Roof Coating for Restoring Aged Metal Roofing Systems (rev. 02/2026)
- Henry Company, Pro-Grade Silicone Roof Coating System Application Guide (04/24)
- The Garland Company, LiquiTec Application Guidelines: LiquiTec Metal Restoration System (©2025, code LT MRS 0125)
- Huntsman Building Solutions, Thermo-Sil Guide Specification: Thermo-Sil Restoration Coating System for Metal Roofs (AN 21.00222, rev. 05.02.22)
- Gaco (Amrize Building Envelope), GW-5-1: GacoFlex Silicone Roof Coatings & Accessories Coverage Rates (rev. 08/2024)
- Gaco (Amrize Building Envelope), Application Specification MR-A47-12-5: GacoFlex A47 Series Acrylic Roof Coating for Restoring Aged Metal Roofing Systems (rev. 1/2026)
- Mule-Hide Products Co., System Specifications 04-1710: 100% Silicone Roof Coating System for Metal Systems (February 2026)
- Roof Coatings Manufacturers Association, in RCI (now IIBEC) Interface, Tech note on coating metal roof panels (May 2004)
- National Bureau of Standards (now NIST), NBSIR 85-3193: Preliminary Recommendations for Maintenance of Factory Coated Metal Siding and Roofing (June 1985)
- IIBEC, Interface, A Deep Dive into Hail-Caused Dents: A Study of Corrosion Resistance within Dents in Galvalume-Coated Steel Roof Panels (Fall 2025)
- Henry Company, Acrylic Restoration & Fluid Applied Membrane Systems Application Guide (04/24)
- American WeatherStar, Application Guideline: Met-A-Sil Roof Restoration System over Metal (last revision 04/14/26)
- The Garland Company, Cool-Sil Application Guidelines: Metal Restoration System (©2026, code 0726)
- Gaco (Amrize Building Envelope), Application Specification MR-P300-23-10: GacoFlex Polyurethane 300 Roof Coating for Restoring Aged Metal Roofing Systems (rev. 04/2026)
- International Code Council, 2021 International Building Code, Chapter 15: Roof Assemblies and Rooftop Structures
- Gaco (Amrize Building Envelope), Product Data Sheet: GacoFlex S42 Series High-Adhesion 100% Silicone Coating (rev. 07/2026)
- USACE / NAVFAC / AFCEC, via the Whole Building Design Guide, UFGS 07 56 00.60 Mesh Reinforced Elastomeric Coating (MREC) Roofing (August 2025, Change 1 February 2026)
- Polyglass U.S.A., Inc., Estimating Guide for Metal Roofs: Liquid-Applied Roof Membranes
- Progressive Materials (PM Silicone), Installation Overview: Silicone Roof Coating Restoration System over Metal Roof Panel (March 2022)
- NRCA, Professional Roofing, Essentials: thermal expansion and contraction of metal roof systems (Joan P. Crowe, October 2003)
- Karnak Corporation, Roof Restoration System METAL Karna-Flex 298: silver reflective coating system application guidelines
- Tremco Roofing and Building Maintenance, Alumanation 301 brochure (2022)
- Tremco Roofing and Building Maintenance, Geogard Finish Coat data sheet
- Gaco (Amrize Building Envelope), Application Specification MR-S42-18-10: GacoFlex S42 Series Elastomeric Silicone Roof Coating for Restoring Aged Metal Roofing Systems (rev. 10/2025)
- FM Approvals, Examination Standard for Class 1 Panel Roofs, Class Number 4471 (03/2025)
Updated October 2026.